Fire protection solutions in accordance with EN 45545-2
Rail transport places high demands on the fire and smoke behaviour of materials. With RAU-SIK 6701, Silnova offers a silicone material developed specifically for rail applications that meets the requirements of EN 45545-2 up to HL3 (R22/R23). In addition to its fire protection properties, the material offers resistance to heat, UV radiation and ageing.
RAU-SIK 6701
RAU-SIK 6701 is a silicone material developed for rail applications. The material meets high requirements for fire and smoke behaviour and can be used in components where safety and compliance with standards play an important role.
Key material properties include:
- Meets the requirements of EN 45545-2 HL3 (R22/R23)
- Meets relevant requirements in accordance with NFPA 130
- High flame retardancy
- Low smoke emissions
- Halogen-free formulation
- High heat resistance
RAU-SIK 6701 can be used in different applications in modern rail vehicles, for example in sealing, profile and protection systems.
EN 45545-2
The European standard EN 45545-2 defines requirements for the fire behaviour of materials and components in rail vehicles. Its aim is to limit the effects of a fire, in particular by reducing the generation and spread of smoke.
Different hazard levels are defined depending on the vehicle type and operating environment. The highest level, HL3, is used in particular for applications with increased safety requirements.
With RAU-SIK 6701, Silnova offers a silicone material that meets the requirements of EN 45545-2 at the highest hazard level, HL3 (R22/R23), making it suitable for applications with high fire protection requirements in the rail sector.
Custom Developments
Do you need a solution for a safety-critical rail application?
Contact us – together, we will develop the right fire protection solution for your project.